<LOGO>
FM Transmitter Measurement Report
Created: 2026-05-10 15-54-50
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 50 dBuV YLEX
Pilot RDS Phase Difference
7.1 kHz 2.1 kHz 72 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 63 kHz 15622 3,1686
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,2 dBr 3,37 dBr 5,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 15:54, 10.05.2026
RT
"YleX Viikonloppu "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6205, 6201, 6203, 6207
FM Scope Max at: 63 kHz MIN: 9 kHz % above 76 kHz: 3,1686 Acquired: 2026/05/10 15.53.45 Total samples: 15622 Equivalent time: 0:13:01 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 5,2 dBr MIN: 0,2 dBr AVE: 3,37 dBr % above 12,2 dBr: 0,0 Last value: 5,2 dBr (2026/05/10 15.53.45) 15.40 15.42 15.44 15.46 15.48 15.50 15.52 0 2 4 6 Pm [dBr]